Purpose
This product is suitable for supporting power supply for oil submersible pump units with rated voltage less than 3KV or less than 6KV.
Usage Characteristics
Conductor long-term working temperature is 150-232°C, with good oil resistance, heat resistance, and corrosion resistance.
Model
Polyimide - F46 composite film sintering / Tri-component ethylene propylene diene monomer rubber composite insulation, lead sheath, polytetrafluoroethylene tape / fiber tape wrapping, galvanized (stainless steel, Monel) steel tape armored flat submersible pump power cable.
Production Range
Voltage: 3KV, 4KV, 5KV, 6KV
Temperature: 150-232°C
Execution Standard: GB/T16750-2015, API RP 11S6

Technical Performance:
|
Quantity of Core |
Nominal Cross Section AWG /mm2 |
Number of Conductors / Diameter mm |
Conductor DC resistance 20℃ ≤ Ω/Km |
Insulation Nominal Value Thickness mm |
Sheath Nominal Value Thickness mm |
Cable Dimensions and Weight (flat cable) |
|||||
|
3KV |
6KV |
||||||||||
|
NO Tinplating |
3KV |
6KV |
3KV |
6KV |
mm×mm |
Kg/Km |
mm×mm |
Kg/Km |
|||
|
3 |
5/16 |
1/4.62 |
1.15 |
1.9 |
2.3 |
1.0 |
1.0 |
13×36 |
2230 |
14×37.5 |
2430 |
|
3 |
4/20 |
1/5.19 |
0.84 |
1.9 |
2.3 |
1.0 |
1.0 |
14×38 |
2464 |
14.5×39 |
2752 |
|
3 |
2/33 |
1/6.54 |
0.55 |
1.9 |
2.3 |
1.0 |
1.0 |
15×43 |
3143 |
16×43 |
3348 |
|
3 |
1/42 |
1/7.35 |
0.44 |
1.9 |
2.3 |
1.0 |
1.0 |
16×45 |
3575 |
17×47 |
3880 |
|
Nominal Cross-sectional Area mm2/AWG |
Nominal Diameter of the Conductor |
1.9 mm Insulation Resistance MΩ·Km |
1.9 mm Leakage Current μA/ (Kv·Km) |
2.3 mm insulation resistance MΩ·Km |
2.3 mm Leakage Current μA/ (Kv·Km) |
DC withstand voltage - 5 minutes |
|
|
3KV |
6KV |
||||||
|
16/5 |
4.62 |
3800 |
0.51 |
4082 |
0.48 |
27 |
35 |
|
20/4 |
5.19 |
3380 |
0.58 |
3738 |
0.50 |
27 |
35 |
|
33/2 |
6.54 |
2650 |
0.63 |
3121 |
0.54 |
27 |
35 |
|
42/1 |
7.35 |
2405 |
0.70 |
2841 |
0.61 |
27 |
35 |
Delivery Requirement:
Delivery can be made within a minimum of 1,000 meters, and it will be packed in full steel corrugated boxes.
Storage and Transportation Instructions:
For the rolled-delivered cables, the outermost layer of the cable should be 100 mm away from the edge of the corrugated all-steel cable reel. The cables must not be knocked against or twisted. Both ends of the cable should be protected against moisture.
FAQ
undefined
Keywords
QYYEQ Type Oil Submersible Power Cable
QYYEQ Type Oil Submersible Power Cable
Classification
Related Products
Oil well heating cable is a product specially designed for oil production. This can significantly improve the average throughput safely, quickly and efficiently.
Continuous Heating Cable of Steel Pipe
The continuous heating system of steel pipes is an electrical heating system that integrates heating and thawing in oil and gas production, liquid and gas transportation through pipelines. Since the protective layer of the cable is a steel pipe, it is compatible with P46, polyethylene, polypropylene cables.
HGL (RDP, JPB) High Temperature Constant Power Electric Heating Belt
The working principle of the HGL type high temperature constant power electric heating belt is the same as that of the HBL type parallel constant power electric heating belt, and its structure is similar.
HBL (RDP, JFB, BL) parallel electric constant power heating belt
A series of constant power parallel electric heating tapes have a constant calorific value per unit length.
Self-adjustable low temperature series
Shandong Huaning designed low temperature self-regulating electric heating belt suitable for common areas, hazardous areas, corrosion zones, etc. D. And used to keep heat, prevent coagulation and freezing. The standard color of the low temperature self-regulating electric heating belt is black or blue, and the main belt can withstand temperatures up to 90 °C.