Product Description
Technical Parameters
Product Features

The explosion-proof temperature thermostat is used in conjunction with the electric heating cable to control the temperature of the heat tracing pipe on site, so that the medium temperature can be controlled within the temperature range required by the process, thereby protecting the electric heating cable and saving energy. It is designed and manufactured according to the requirements of increased safety explosion-proof electrical appliances. Applicable to the explosive gas environment in the first and second zones of the factory.

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Model

BJW-51

BJW-51-D2

Rated voltage

220V

380V

220V

Rated current

≤16A

≤16A

≤16A

Temperature control range

0-120℃

0-120℃

0-120℃

Temperature control accuracy

±2.5℃

±2.5℃

±2.5℃

Cable import

G3/4″

G3/4″

G3/4″

Explosion-proof mark

ExeⅡT4

ExeⅡT4

ExeⅡT4

Protection level

IP54

IP54

IP54

Appearance size

200*140*75

200*140*75

168*167*80

Work indicator

No

No

Have

Before installation, please carefully check the temperature controller (such as damage, deformation, looseness, etc.), otherwise it is not allowed to install and replace it in time. Turn on the temperature controller to find the temperature adjustment knob, adjust to the room temperature to hear the sound of the relay action, and use a multimeter to measure the on/off status of the corresponding terminal. Normally adjust the temperature to the temperature you want to control and tighten the lid. When connecting the internal wiring, the connecting wire should be tightened. It is strictly forbidden to entangle the cores in the terminal box to ensure sufficient electrical clearance. The size of the sealing rubber ring should be matched with the size of the heating cable during installation, and it should not be exchanged at will to ensure the explosion-proof performance. All fixed screws are tightened to ensure explosion-proof performance. Fix the temperature controller in place with the clamp and attach the temperature probe to the temperature of the measured temperature. The temperature control probe should be horizontal or vertical and keep a certain distance of 3-5cm from the electric heating cable to avoid measurement. The temperature of the equipment is not accurate or unstable.

Previous
Next

Online Message

Username used for comment:
客户留言
Description:

About Us

News Center

这是描述信息

scan it

这是描述信息

Service Hotline

0531-88612345

Headquarters telephone:0531-88612345
After sales call:800-860-6576
Headquarters address:Building 105-106, Building 16, Phase 4, Times Headquarters, No. 30 Lanxiang Middle Road, Tianqiao District, Jinan, Shandong, China

Production base:Xinxing Street, Industrial Park, Shanghe County, Jinan City

copyright © 2019 Shandong Huaning Electric Heating Technology Co., Ltd            鲁ICP备10203882号-1            Powered by:www.300.cn  Jinan