Method of active heating, thermal insulation and protection against freezing of tunnels in high mountain areas thermal insulation layer electric heating Method of active heating, thermal insulation and protection against freezing of tunnels

Freezing damage often threatens the construction and normal operation of tunnels in cold regions. In recent years, low-temperature heating cable laying system has become widespread due to its unique advantages.

Apr 01,2023

Freezing damage often threatens construction and normal operation of tunnels in cold regions. In recent years, the low-temperature heating cable laying system has become widespread due to its unique advantages, among which the most common and fastest growing is the floor heating system, which needs to be used in airports, stadiums, and large residential areas in China. Electric radiant heating technology.

The electric heating system is a radiation heating system. An electric heating wire is used as a heat carrier. After the electrification of the heating cable, the electric energy is converted into thermal energy, which is transferred to the heated body, and the heat is stored, the outer layer of the thermal insulation material is used to meet the requirements of the heating and insulation effect. Heating cables generally consist of the following parts: heating wires, insulating layers, metal shielding layers, waterproof and anti-corrosion shells, etc. D., and the trunk cables also have metal-reinforced shells. It can be divided into two types: limited car port and self-limited type in terms of heating type. At present, the most commonly used electric heating tape is a self-regulating heating tape, and the resistivity of its heating element has a very high positive temperature coefficient. The electric heating system is a radiation heating system. An electric heating wire is used as a heat carrier. After the electrification of the heating cable, the electric energy is converted into thermal energy, which is transferred to the heated body, and the heat is preserved, the outer layer of the thermal insulation material is used to meet the requirements of the heating and insulation effect system. Heating cables generally consist of the following parts: heating wires, insulating layers, metal shielding layers, waterproof and anti-corrosion shells, etc. D., and the trunk cables also have metal-reinforced shells. It can be divided into two types: limited car port and self-limited type in terms of heating type. At present, the most commonly used electric heating tape is a self-regulating heating tape, and the resistivity of its heating element has a very high positive temperature coefficient.

In order to effectively avoid frost damage to the tunnel, the “heat insulation layer electric heating” system can be used at the entrance to the tunnel.

After a lot of tunnel thermal insulation and electric heating system test projects have been used, the thermal insulation and antifreeze method for the laying of thermal insulation layer and active heating of heating cable has high feasibility and efficiency.

TAG:

Related Posts

Electrical heating installation precautions

Electric heating cable is a heating method that uses insulation resistance or resistance heating wire to create a temperature after power supply. It can automatically adjust the output temperature and reasonably maintain the process temperature requirements to keep warm, raise the temperature and protect the heating equipment from freezing. The insulation and antifreeze effect of the container is very good.

Which electric heating should be chosen for the main pipeline transport of heavy oil

Transport of heavy oil through the pipeline over long distances and long-term retention in the pipeline will result in a drop in temperature due to heat dissipation and increased viscosity, which will cause the pipeline to be blocked by freezing or condensation-related accidents. Electric heating is widely used as effective insulation of pipelines and anti-freeze protection.

Which electric heating cable should be considered for a 4 km pipeline

According to the statistics of the Hydrometeorological Center, the average daily minimum temperature at the location of the CNPC tank farm is 5 ° C, and the average daily maximum temperature is 14 ° C. Since the freezing point of the PX is about 15 °C, the supply pipeline needs heat preservation and heating. The oil depot has been in operation for many years without a stable source of steam, therefore, this project is considering the use of electric heating technology.

Application of outdoor electric heating cable in oil main pipelines with high paraffin content

Long-distance crude oil pipelines with a high paraffin content with freezing temperatures above 50 °C. According to the requirements of the production plan of the plant, the volume of oil transportation through the pipeline is 150 thousand rubles. Tons per year, maximum-200 thousand. Tons per year.. According to the thermodynamic analysis of the pipeline, the initial supply temperature of the pipeline is 80 ° C (TN), and the temperature of the end entering the tank is 60 ° C (Tu). Since the transportation temperature needs to be adjusted according to the time of year, it sometimes needs to be transported by heat.

What heating product to choose for main infusion pipelines

In petrochemical engineering, trunk infusion pipelines are the lifeblood of the factories. The temperature in the northern region is too low in winter and the pipeline needs to be insulated to compensate for the heat loss due to the low temperature in winter to ensure the normal operation of the pipeline.

The role of leather tracer cables in the insulation of asphalt main pipelines

The toughness of the asphalt is greatly affected by the temperature. When the temperature decreases, the toughness of the asphalt increases, and the drop in resistance of the asphalt during pipeline transportation increases; when the temperature falls below the freezing point, the asphalt solidifies, causing the pipeline to clog and the conveyor belt to come to trouble. Therefore, electric heating and heat preservation during the transportation of asphalt are very important.