Application of self-regulating electric heating cable on high speed rail Application of self-regulating electric heating cable on high speed rail
In railway vehicles, equipment such as water and drainage pipelines, sewer lines, vacuum piping and boxes under vehicles use heating cables to heat antifreeze.
Jan 12,2023
Self-regulating heating cable is a ribbon electric heating element that is extruded from a conductor, heating material, and insulation layer and has a metallic or non-metallic sheath that can itself limit the maximum heating temperature. The heating cable is generally used to cover the surface of an object in a flat or wound way. The installation method is flexible and can be determined by the shape of the object being heated. It is widely used in antifreeze, process maintenance or heating. Pipelines, boxes, silo equipment and other systems.

In railway vehicles, equipment such as water and drainage piping, sewer piping, vacuum piping, and boxes under vehicles use heating cables to heat antifreeze. The heating element of the heating cable is a material with a positive temperature coefficient containing conductive particles, the material is uniformly extruded between two parallel metal tires, and the conductive particles are connected across the two tires to form several parallel circuits. Valve body, the heating element can automatically adjust the output power according to the temperature of the heated system, adjust the heat generated, so as to achieve the purpose of automatic temperature limitation, to ensure that the working system is always normal. Set the optimal working temperature zone.

(1) Copper core tire: 19 × 0.32, 7 × 0.5
(2) Heating core belt: Fluorine PTC
(3) Insulation layer: Fluorinated polyolefin, perfluorinated material.
(4) Shielding layer: Tinned copper wire braid or another metal wire braid with a coating density of ≥ 80%.
(5) Shell Layer: Fluorinated Polyolefin, Perfluorinated Material.
Electric heating parameters of self-control temperature
(1) Standard color: black/blue
(2) Temperature range: The maximum operating temperature is 65 ± 5 °C and the maximum temperature to be sustained is 90 °C.
(3) Design temperature: Polyolefin minimum-20 °C, Fluorine material minimum-60 °C
(4) Start current: ≤ 0.5 A/m
(5) Thermal stability: After the electric heating belt has passed the thermal performance test, its power should be maintained at 90% of the original value.
(6) Bending radius: 25.4mm at-20 °C, 35mm at-60 °C
(7) Insulation resistance: The insulation resistance between the electric heating conductor and the metal shielding layer shall be at least 50 Mhm.
Related Posts
Electrical heating installation precautions
Electric heating cable is a heating method that uses insulation resistance or resistance heating wire to create a temperature after power supply. It can automatically adjust the output temperature and reasonably maintain the process temperature requirements to keep warm, raise the temperature and protect the heating equipment from freezing. The insulation and antifreeze effect of the container is very good.
Which electric heating should be chosen for the main pipeline transport of heavy oil
Transport of heavy oil through the pipeline over long distances and long-term retention in the pipeline will result in a drop in temperature due to heat dissipation and increased viscosity, which will cause the pipeline to be blocked by freezing or condensation-related accidents. Electric heating is widely used as effective insulation of pipelines and anti-freeze protection.
Which electric heating cable should be considered for a 4 km pipeline
According to the statistics of the Hydrometeorological Center, the average daily minimum temperature at the location of the CNPC tank farm is 5 ° C, and the average daily maximum temperature is 14 ° C. Since the freezing point of the PX is about 15 °C, the supply pipeline needs heat preservation and heating. The oil depot has been in operation for many years without a stable source of steam, therefore, this project is considering the use of electric heating technology.
Application of outdoor electric heating cable in oil main pipelines with high paraffin content
Long-distance crude oil pipelines with a high paraffin content with freezing temperatures above 50 °C. According to the requirements of the production plan of the plant, the volume of oil transportation through the pipeline is 150 thousand rubles. Tons per year, maximum-200 thousand. Tons per year.. According to the thermodynamic analysis of the pipeline, the initial supply temperature of the pipeline is 80 ° C (TN), and the temperature of the end entering the tank is 60 ° C (Tu). Since the transportation temperature needs to be adjusted according to the time of year, it sometimes needs to be transported by heat.
What heating product to choose for main infusion pipelines
In petrochemical engineering, trunk infusion pipelines are the lifeblood of the factories. The temperature in the northern region is too low in winter and the pipeline needs to be insulated to compensate for the heat loss due to the low temperature in winter to ensure the normal operation of the pipeline.
The role of leather tracer cables in the insulation of asphalt main pipelines
The toughness of the asphalt is greatly affected by the temperature. When the temperature decreases, the toughness of the asphalt increases, and the drop in resistance of the asphalt during pipeline transportation increases; when the temperature falls below the freezing point, the asphalt solidifies, causing the pipeline to clog and the conveyor belt to come to trouble. Therefore, electric heating and heat preservation during the transportation of asphalt are very important.